DIGITAL TYPE ROGOWSKI COIL CURRENT TRANSFORMER


Adopt magnetic shielding flexible core piercing structure, the current transformer and current transmitter are combined into one body design.

<p><span style="color: #333333;">DIGITAL TYPE ROGOWSKI COIL CURRENT TRANSFORMER</span></p>

Rogowski Coil Current Transformer

Rogowski coil current transformer—also known as rogowski coil flexible current transformers—are highly flexible current measurement devices designed for precise AC current testing and high-current monitoring.


Thanks to rogowski coil current transformer flexible structure, these coils can easily wrap around large or irregularly shaped conductors, as well as cables with narrow spacing, without requiring any disconnection of the primary circuit. This unique design makes them ideal for use in temporary measurements, retrofit installations, or systems where traditional rigid-core CTs cannot be applied.

Each coil is built with advanced materials and precision manufacturing to ensure stable performance, strong anti-interference capability, and long service life. Additionally, customizable colors and specifications are available to meet diverse installation and branding requirements.

Key Features of Rogowski Coil Current Transformers

Unlike traditional current transformers, the Rogowski coil uses a non-magnetic, air-cored design, making it exceptionally lightweight, adaptable, and easy to install in complex environments.
Key Features of Rogowski Coil Current Transformers
Here are 3 key features:
  • icon
    Flexible and Easy Installation
    The coil’s flexible, non-magnetic design allows it to wrap around large or irregularly shaped conductors without disconnecting cables, making it ideal for retrofit and temporary measurements.
  • icon
    Wide Measurement Range and Excellent Linearity
    Capable of accurately measuring both low and very high AC currents, Rogowski coils maintain excellent linearity across a broad frequency range, ensuring precise current monitoring and waveform capture.
  • icon
    Lightweight and Non-Intrusive Design
    With no magnetic core, Rogowski coil transformers are compact, lightweight, and free from magnetic saturation issues—providing safe, reliable performance with minimal impact on the primary circuit.

Industry Applications

Mibo Electric’s Rogowski coil current transformers deliver high accuracy, excellent linearity, and wide frequency response, making them suitable for both industrial and commercial power monitoring applications. They are widely used in: Power quality analysis and energy metering systems; High-current AC testing and fault detection; Smart grid monitoring and harmonic analysis; Electrical maintenance and transient current measurement.

Low-Voltage Open-Type (Split-Core) Current Transformers - Frequently Asked Questions (FAQ)

  • >Q: Can the secondary side of an open-type CT be open-circuited?

    A: Absolutely not! This requirement is identical to that for solid-core CTs. An open secondary circuit during operation will induce an extremely high voltage, posing a severe safety hazard and potentially breaking down the CT's internal insulation, permanently destroying it. Always ensure the secondary circuit is securely connected or its terminals are shorted before applying power.

  • >Q: Do open-type CTs require maintenance?

    A: They require very little maintenance, but periodic checks are advisable:

    Mechanical Check: Inspect the latching mechanism for smooth operation, looseness, or corrosion.

    Cleaning: Wipe the surface with a dry, soft cloth to remove dust and maintain insulation properties.

    Tightness Check: Ensure the CT is securely fixed to the conductor and/or mounting surface.

    Circuit Check: Inspect secondary wiring terminals for looseness or oxidation.

  • >Q: My CT is installed correctly, but the reading is significantly low or unstable. What could be the cause?

    A: Core Not Fully Closed: This is the most common cause. Check if the latch or hinge is fully engaged.

    External Magnetic Interference: The CT is installed too close to another high-current conductor. Move it away.

    Excessive Secondary Burden: The impedance of the connected devices exceeds the CT's rated burden (VA value), causing increased error. Check the CT's specifications and the input impedance of your measuring device.

    CT and Equipment Mismatch: For example, connecting a 5A output CT to a 1A input meter, or connecting a voltage-output CT to a current-input interface

  • >Q: How do I choose a suitable open-type current transformer?

    A: Consider the following key parameters:

    Bore Diameter (Inner Diameter): This is the most critical parameter! It must be larger than the maximum outer diameter of the cable or busbar to be measured, with sufficient room for installation and heat dissipation.

    Rated Current (Ratio): Selected based on the line's normal operating current and potential maximum current. E.g., for a 200A circuit, choose a 250/5A or 300/5A ratio.

    Accuracy Class: Class 0.5 is recommended for energy metering; Class 1.0 is acceptable for general monitoring.

    Frequency: Typically 50/60Hz.

    Output Type:

    Traditional 5A/1A Output: For connection to analog panel meters or older energy meters.

    Voltage Output (e.g., 0-1V, 0-5V): For direct connection to analog input ports on PLCs or data acquisition modules.

    Milliampere Output (e.g., 4-20mA): Used for long-distance signal transmission due to high noise immunity.

    Mounting Style: Check for DIN rail mounting slots, mounting feet, or other fixing options.

  • >Q: What are the advantages and disadvantages of using an open-type CT?

    A: Advantages:

    1.  Easy Installation: The biggest advantage. Allows for installation without a power outage, avoiding disruption to operations.
    2.  High Flexibility: Can be easily added to any circuit at any time.
    3.  Safety: Eliminates the risks and hassles associated with de-energizing equipment.

    Disadvantages:

    1.  Generally Lower Accuracy: The air gap at the core joint makes the magnetic path less perfect than a solid core, potentially increasing magnetic reluctance and measurement error (especially phase error). Accuracy is typically Class 1.0 or 0.5.
    2.  Higher Cost: The more complex structure leads to a higher manufacturing cost compared to equivalent solid-core CTs.
    3.  Mechanical Reliability: The hinge or latch mechanism is a potential weak point and must be ensured to close tightly and reliably.
  • >Q: What are the main applications for open-type CTs?

    A: Their primary application scenarios include:

    Energy Metering: Retrofitting existing distribution boards and panels to add energy meters for audit or sub-metering.

    Power Monitoring Systems (SCADA): Real-time monitoring of current, power, and other parameters in branch circuits within smart buildings, data centers, and factory production lines.

    Troubleshooting & Energy Analysis: Temporary connection to circuits for power surveys and load analysis.

    Reactive Power Compensation Control: Providing current sampling signals for capacitor compensation banks.

  • >Q: What are the special precautions when installing an open-type CT?

    A:Ensure Tight Closure: After installation, you must ensure the core is fully closed and latched. Any gap will increase magnetic reluctance, severely degrading measurement accuracy, and may cause humming.

    Correct Orientation: CTs are usually marked with "P1" (line side) and "P2" (load side) or an arrow indicating the direction of current flow. Incorrect installation affects phase measurement, which is critical for power and energy calculation.

    Avoid Interference: Keep the CT away from other high-current busbars, reactors, or strong magnetic fields. Maintain a distance of at least 10 times the bore diameter to minimize external magnetic interference.

    Center Single Conductor: For a single cable, position it as close to the center of the bore as possible for optimal accuracy.

     

  • >Q: What is an open-type current transformer? What is the biggest difference between it and a solid-core transformer?

    A: An open-type current transformer, also known as a split-core transformer, has a core made of two parts that can be opened and closed via a hinge or latch mechanism. The biggest difference is:

    Open-Type CT: Does not require disconnecting the conductor or busbar to be measured. It simply "clamps" around the live conductor, making it ideal for retrofitting existing, live circuits or for monitoring where shutdown is inconvenient.

    Solid-Core CT: The core is a single piece. It must be installed by threading the conductor through the center before termination or during initial wiring, requiring a power shutdown for installation.

  • >Q: Why can’t I just clamp multiple cables into one large CT for measurement?

    A: This is strictly prohibited. According to Kirchhoff's Current Law, the sum of currents in a node is zero. If you clamp live and neutral conductors (or all three phases A/B/C) together, their magnetic fields will cancel each other out, resulting in near-zero output from the CT. One open-type CT must only clamp around a single live conductor.

  • >Q: Why do I need to set the “Ratio” on an energy meter when using it with an open-type CT? How is it set?

    A: The CT's function is to scale down the primary current. The energy meter itself only measures this scaled-down secondary current. Setting the ratio informs the meter of this scaling factor so it can calculate the true primary current and power.

    How to Set: If the CT ratio is 300/5A, then the ratio = 300 / 5 = 60. In the energy meter's parameter settings, set the "CT Ratio" or "Current Multiplier" to 60.